Energy Measurement Infrastructure

All nodes of the HPC machine Taurus are equipped with power instrumentation that allow the recording and accounting of power dissipation and energy consumption data. The data is made available through several different interfaces, which will be described below.

System Description

The Taurus system is split into two phases. While both phases are equipped with energy-instrumented nodes, the instrumentation significantly differs in the number of instrumented nodes and their spatial and temporal granularity.

Phase 1

In phase one, the 270 Sandy Bridge nodes are equipped with node-level power instrumentation that is stored in the Dataheap infrastructure at a rate of 1Sa/s and further the energy consumption of a job is available in SLURM (see below).

Phase 2

In phase two, all of the 1456 Haswell DLC nodes are equipped with power instrumentation. In addition to the access methods of phase one, users will also be able to access the measurements through a C API to get the full temporal and spatial resolution, as outlined below:
  • Blade: 1 kSa/s for the whole node, includes both sockets, DRAM, SSD, and other on-board consumers. Since the system is directly water cooled, no cooling components are included in the blade consumption.
  • Voltage regulators (VR): 100 Sa/s for each of the six VR measurement points, one for each socket and four for eight DRAM lanes (two lanes bundled).
The GPU blades of each Phase as well as the Phase I Westmere partition also have 1 Sa/s power instrumentation but have a lower accuracy.

HDEEM is now generally available on all nodes in the "haswell" partition.

Summary of Measurement Interfaces

Interface Sensors Rate Phase I Phase II Haswell
Dataheap (C, Python, VampirTrace, Score-P) Blade, (CPU) 1 Sa/s yes yes
HDEEM* (C, Score-P) Blade, CPU, DDR 1 kSa/s (Blade), 100 Sa/s (VRs) no yes
HDEEM Command Line Interface Blade, CPU, DDR 1 kSa/s (Blade), 100 Sa/s (VR) no yes
SLURM Accounting (sacct) Blade Per Job Energy yes yes
SLURM Profiling (hdf5) Blade up to 1 Sa/s yes yes
Note: Please specify -p haswell --exclusive along with your job request if you wish to use hdeem.

Accuracy

HDEEM measurements have an accuracy of 2 % for Blade (node) measurements, and 5 % for voltage regulator (CPU, DDR) measurements.

Command Line Interface

The HDEEM infrastructure can be controlled through command line tools that are made available by loading the hdeem module. They are commonly used on the node under test to start, stop, and query the measurement device.

  • startHdeem: Start a measurement. After the command succeeds, the measurement data with the 1000 / 100 Sa/s described above will be recorded on the Board Management Controller (BMC), which is capable of storing up to 8h of measurement data.
  • stopHdeem: Stop a measurement. No further data is recorded and the previously recorded data remains available on the BMC.
  • printHdeem: Read the data from the BMC. By default, the data is written into a CSV file, whose name can be controlled using the -o argument.
  • checkHdeem: Print the status of the measurement device.
  • clearHdeem: Reset and clear the measurement device. No further data can be read from the device after this command is executed before a new measurement is started.

Integration in Application Performance Traces

The per-node power consumption data can be included as metrics in application traces by using the provided metric plugins for Score-P (and VampirTrace). The plugins are provided as modules and set all necessary environment variables that are required to record data for all nodes that are part of the current job.

For 1 Sa/s Blade values (Dataheap):
  • Score-P: use the module scorep-dataheap
  • VampirTrace: use the module vampirtrace-plugins/power-1.1
For 1000 Sa/s (Blade) and 100 Sa/s (CPU{0,1}, DDR{AB,CD,EF,GH}):
  • Score-P: use the module scorep-hdeem
    Note: This module requires a recent version of "scorep/sync-...". Please use the latest that fits your compiler & MPI version.
  • VampirTrace: not supported
By default, the modules are set up to record the power data for the nodes they are used on. For further information on how to change this behavior, please use module show on the respective module.

# Example usage with gcc
% module load scorep/trunk-2016-03-17-gcc-xmpi-cuda7.5
% module load scorep-dataheap
% scorep gcc application.c -o application
% srun ./application

Once the application is finished, a trace will be available that allows you to correlate application functions with the component power consumption of the parallel application. Note: For energy measurements, only tracing is supported in Score-P/VampirTrace. The modules therefore disables profiling and enables tracing, please use Vampir to view the trace.

demoHdeem_high_low_vampir_3.png

Note: the power measurement modules scorep-dataheap and scorep-hdeem are dynamic and only need to be loaded during execution. However, scorep-hdeem does require the application to be linked with a certain version of Score-P.

By default, scorep-dataheap records all sensors that are available. Currently this is the total node consumption and for Phase II the CPUs. scorep-hdeem also records all available sensors (node, 2x CPU, 4x DDR) by default. You can change the selected sensors by setting the environment variables:
# For HDEEM
% export SCOREP_METRIC_HDEEM_PLUGIN=Blade,CPU*
# For Dataheap
% export SCOREP_METRIC_DATAHEAP_PLUGIN=localhost/watts

For more information on how to use Score-P, please refer to the respective documentation.

Access Using Slurm Tools

Slurm maintains its own database of job information, including energy data. There are two main ways of accessing this data, which are described below.

Post-Mortem Per-Job Accounting

This is the easiest way of accessing information about the energy consumed by a job and its job steps. The Slurm tool sacct allows users to query post-mortem energy data for any past job or job step by adding the field ConsumedEnergy to the --format parameter:

$> sacct --format="jobid,jobname,ntasks,submit,start,end,ConsumedEnergy,nodelist,state" -j 3967027
       JobID    JobName   NTasks              Submit               Start                 End ConsumedEnergy        NodeList      State 
------------ ---------- -------- ------------------- ------------------- ------------------- -------------- --------------- ---------- 
3967027            bash          2014-01-07T12:25:42 2014-01-07T12:25:52 2014-01-07T12:41:20                    taurusi1159  COMPLETED 
3967027.0         sleep        1 2014-01-07T12:26:07 2014-01-07T12:26:07 2014-01-07T12:26:18              0     taurusi1159  COMPLETED 
3967027.1         sleep        1 2014-01-07T12:29:06 2014-01-07T12:29:06 2014-01-07T12:29:16          1.67K     taurusi1159  COMPLETED 
3967027.2         sleep        1 2014-01-07T12:33:25 2014-01-07T12:33:25 2014-01-07T12:33:36          1.84K     taurusi1159  COMPLETED 
3967027.3         sleep        1 2014-01-07T12:34:06 2014-01-07T12:34:06 2014-01-07T12:34:11          1.09K     taurusi1159  COMPLETED 
3967027.4         sleep        1 2014-01-07T12:38:03 2014-01-07T12:38:03 2014-01-07T12:39:44         18.93K     taurusi1159  COMPLETED  

The job consisted of 5 job steps, each executing a sleep of a different length. Note that the ConsumedEnergy metric is only applicable to exclusive jobs.

Slurm Energy Profiling

The srun tool offers several options for profiling job steps by adding the --profile parameter. Possible profiling options are All, Energy, Task, Lustre, and Network. In all cases, the profiling information is stored in an hdf5 file that can be inspected using available hdf5 tools, e.g., h5dump. The files are stored under /scratch/profiling/ for each job, job step, and node. A description of the data fields in the file can be found here. In general, the data files contain samples of the current power consumption on a per-second basis:
$> srun -p sandy --acctg-freq=2,energy=1 --profile=energy  sleep 10 
srun: job 3967674 queued and waiting for resources
srun: job 3967674 has been allocated resources
$> h5dump /scratch/profiling/jschuch/3967674_0_taurusi1073.h5
[...]
               DATASET "Energy_0000000002 Data" {
                  DATATYPE  H5T_COMPOUND {
                     H5T_STRING {
                        STRSIZE 24;
                        STRPAD H5T_STR_NULLTERM;
                        CSET H5T_CSET_ASCII;
                        CTYPE H5T_C_S1;
                     } "Date_Time";
                     H5T_STD_U64LE "Time";
                     H5T_STD_U64LE "Power";
                     H5T_STD_U64LE "CPU_Frequency";
                  }
                  DATASPACE  SIMPLE { ( 1 ) / ( 1 ) }
                  DATA {
                  (0): {
                        "",
                        1389097545,  # timestamp
                        174,         # power value
                        1
                     }
                  }
               }

Using the HDEEM C API

Note: Please specify -p haswell --exclusive along with your job request if you wish to use hdeem.

Please download the offical documentation at http://www.bull.com/download-hdeem-library-reference-guide

The HDEEM headers and sample code are made available via the hdeem module. To find the location of the hdeem installation use
% module show hdeem
------------------------------------------------------------------- 
/sw/modules/taurus/libraries/hdeem/2.1.9ms: 

conflict         hdeem  
module-whatis    Load hdeem version 2.1.9ms  
prepend-path     PATH /sw/taurus/libraries/hdeem/2.1.9ms/include  
setenv           HDEEM_ROOT /sw/taurus/libraries/hdeem/2.1.9ms 
-------------------------------------------------------------------

You can find an example of how to use the API under $HDEEM_ROOT/sample.

Access Using the Dataheap Infrastructure

In addition to the energy accounting data that is stored by Slurm, this information is also written into our local data storage and analysis infrastructure called Dataheap. From there, the data can be used in various ways, such as including it into application performance trace data or querying through a Python interface.

The Dataheap infrastructure is designed to store various types of time-based samples from different data sources. In the case of the energy measurements on Taurus, the data is stored as a timeline of power values which allows the reconstruction of the power and energy consumption over time. The timestamps are stored as UNIX timestamps with a millisecond granularity. The data is stored for each node in the form of nodename/watts, e.g., taurusi1073/watts. Further metrics might already be available or might be added in the future for which information is available upon request.

Note: The dataheap infrastructure can only be accessed from inside the university campus network.

Using the Python Interface

The module dataheap/1.0 provides a Python module that can be used to query the data in the Dataheap for personalized data analysis. The following is an example of how to use the interface:
import time
import os
from dhRequest import dhClient

# Connect to the dataheap manager
dhc = dhClient()
dhc.connect(os.environ['DATAHEAP_MANAGER_ADDR'], int(os.environ['DATAHEAP_MANAGER_PORT']))

# take timestamps
tbegin = dhc.getTimeStamp() 
# workload
os.system("srun -n 6 a.out")
tend   = dhc.getTimeStamp()

# wait for the data to get to the
# dataheap
time.sleep(5)

# replace this with name of the node the job ran on
# Note: use multiple requests if the job used multiple nodes
countername = "taurusi1159/watts"

# query the dataheap
integral = dhc.storageRequest("INTEGRAL(%d,%d,\"%s\", 0)"%(tbegin, tend, countername))
# Remember: timestamps are stored in millisecond UNIX timestamps
energy   = integral/1000

print energy

timeline = dhc.storageRequest("TIMELINE(%d,%d,\"%s\", 0)"%(tbegin, tend, countername))

# output a list of all timestamp/power-value pairs
print timeline

More information and Citing

More information can be found in the paper HDEEM: high definition energy efficiency monitoring by Hackenberg et al. Please cite this paper if you are using HDEEM for your scientific work.